Unified Technology Solution Logo

We provide professional design, consultation, installation amd material supply: fire alarm system
Telecommunication System • CCTVSystem • Fire Alarm System
• PA System & Conference System • Access Control System

Addressable Fire Alarm System

Notifier FSP-851

Photoelectric smoke detection
Analog communications, Low standby current
Rotary address switches, Dual LEDs for 360° visibility

Notifier FST-851

Intelligent
With FlashScan
 

Notifier Horn-Strobes

Candela - Selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd
DC Max Op Current, FWR Max Op Current, Maximum Humidity - 10 to 93% non-condensing, Operating Temperature - -40°F to 151°F (-40°C to 66°C), Operating Voltage Range - 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal),, Voltage - Regulated 12DC/FWR or regulated 24DC/FWR

Notifier LCM-320

Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop(twisted-unshielded)
Built-in degraded mode increases survivability
Very simple installation - plug-in style
Permits multiple loops in small enclosure.

 
 

Notifier NBG-12LX

Shipping Weight: 9.6 oz. (272.15 g)
Normal operating voltage: 24 VDC
Maximum SLC loop voltage: 28.0 VDC
Maximum SLC standby current: 375 μ A
Maximum SLC alarm current: 5 mA
Temperature Range: 32°F to 120°F (0°C to 49°C)
Relative Humidity: 10% to 93% (noncondensing)
For use indoors in a dry location

Notifier NFS2-640

Signaling Line Circuits (SLCs) 1 expandable to 2
159 detectors/159 modules per SLC
Notification Appliance Circuits (NACs) 4 (built in); 1.5 amps, Voice Evacuation Available Yes: with integrated Digital Voice Command
Power 6 amps total system power Annunciators 32 LCD type 32 ACS type
Networkable Yes: NOTI-FIRE-NET

Notifier NFS-320E

Signaling Line Circuits (SLCs)1
Intelligent Devices 318: (159 detectors/159 modules)
Notification Appliance Circuits (NACs) 4 (built in): 1.5 amps, Voice Evacuation Available Yes: Direct integration with FirstCommand 50/100
Power 6 amps total system power
Annunciators 32 LCD type, 32 ACS type
Networkable Yes: NOTI-FIRE-NET

Notifier AW FP-100 Series

7” Touchscreen LCD Color Display
Delay function for zones for Notification Appliance Circuits (NACs), 2 wire cable for all addressable devices
Zone test and individual device testing
Zone Disable and individual device isolation
Delay, override and abort functionality
User friendly : easily configurable windows using Panel...

Read More →

Conventional Fire Alarm System

System Sensor 800 Series Detectors

Diameter:10.2 cm(4"), Height(including base):4.8 cm(1.8"), Operating Temperature Range: 0~38°C(32°Fto100°F), Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing, Max. Air Velocity:20m/s, Latching Alarm: Reset by momentary power interruption, Sensitivity:63°C(145.4°F) Fixed, Operating Voltage: 8.5~30 VDC, Standby Current: ≤ 50µA, Alarm Current: Min.: 2 mA, Max.: 130mA

Notifier 5600 Series

Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise, 135°F or 194°F ratings, Plain housing for residential installations (Model 5601P), Easy-to-use terminal screws, A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring
Reversible mounting bracket

Silent Knight SK-5208

Operating Voltage: 24 VDC
Primary AC: 120 Vrms @ 60Hz, 2A
Total DC Load: 6 Amp
Current Draw: Standby: 140 mA
Alarm: 460 mA
Operating Temp: 32° to 120° F (0° to 49° C)

System Sensor SSM/SSV Series Alarm Bells

Approved for indoor and outdoor use, Low current draw, High dB output, Available in six-inch, eight-inch, and ten-inch sizes, AC and DC models, DC models polarized for use with supervision circuitry, Mount directly to standard four-inch square electrical box indoors, SSM and SSV series come pre-wired

Notifier NBG-12S

Shipping Weight: 9.6 oz. (272.15 g), Normal operating voltage: 24 VDC, Maximum SLC loop voltage: 28.0 VDC, Maximum SLC standby current: 375 μ A, Maximum SLC alarm current: 5 mA, Temperature Range: 32°F to 120°F (0°C to 49°C), Relative Humidity: 10% to 93% (noncondensing), For use indoors in a dry location

Notifier SFP-2404

Initiating Device Circuits
Notification Appliance Circuits (NACs)
Voice Evacuation Available Yes: requires direct connect to FireVoice 25/50 Power
3.0 amps total system power;
SFP-2404 expandable to 6 amps
 

Asenware AW-CBL2166-A-6

Diameter : 6"(150mm)
Volume(dB) : 95
Work Voltage: DC6V/DC12V/DC24V/AC110V/AC230V

Asenware AW-CFP2166-08

Mains supply voltage : 110VAC or 240VAC
Maximum number of manual call points per zone
Output type : NC and NO relay

Asenware AW-CTD821

Operating Voltage Range 9 to 28 VDC Volts Non-polarized, Standby Current ≤120µA @ 24 VDC, Maximum Alarm Current (LED on) ≤15mA@24VDC (1K Ohm current-limiting resistance), Operating Humidity Range ≤95%RH(40ºC±2ºC) Relative Humidity, Non-condensing, Operating Temperature Range -10ºC to 50ºC (14ºF to 122ºF)

Asenware AW-CMC2166-1

Working Voltage: 220VAC/50Hz or 24VDC
Maximum Current: 5A (220VAC/50Hz) or 8A(24VDC)
Contactor Resistance: ≤0.1
Working Temperature: -10~+50ºC
Relative Humidity: max ≤93±2%
 

Asenware AW-CSD811

Operating Voltage Range: 9 to 28 VDC Volts Non-polarized, Standby Current: ≤120µA @ 24 VDC
Maximum Alarm Current (LED on: ) ≤15mA @ 24 VDC
(1k Ohm current-limiting resistance)
Operating Humidity Range: ≤95% Relative Humidity, Non-condensing

Contact Us

  • No.361, Lower Kyeemyindaing Road,
    (Near Academy Hospital), Ahlone Township,
    Yangon, Myanmar

    telephone Hot Line : (+95)9 450 450 706, 944088391~4
    telephone (+95)1-513221 | Fax: (+95)1-513221
    Email sales@ut-s.com, services@ut-s.com, project@ut-s.com
    Website http://www.ut-s.com

    Singapore Address : UTS Trading Pte Ltd, 111 North Bridge Road, #13-01 Peninsula Plaza, Singapore 179098