Unified Solution Logo
We provide professional design, consultation, installation amd material supply:
Telecommunication System • CCTVSystem • Fire Alarm System
• PA System & Conference System • Access Control System
You are here arrow -> Home > Products > Fire Alarm System
Addressable Fire Alarm System
Notifier FSP-851 Notifier FSP-851

Sensitivity: 0.5% to 2.35% per foot obscuration
Size: 2.1" (5.3 cm) high; base determines diameter.
-B210LP(A): 6.1" (15.5 cm) diameter.
-B501(A): 4.1" (10.4 cm) diameter.
-B200S(A): 6.875" (17.46 cm) diameter.

Notifier FST-851 Notifier FST-851

Intelligent
With FlashScan

Notifier Horn-Strobes Notifier Horn-Strobes

Candela - Selectable strobe settings of 15, 15/75, 30, 75, 95, 110 and 115 cd
DC Max Op Current
FWR Max Op Current
Maximum Humidity - 10 to 93% non-condensing
Operating Temperature - -40°F to 151°F (-40°C to 66°C)
Operating Voltage Range - 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal)
Voltage - Regulated 12DC/FWR or regulated 24DC/FWR

Notifier LCM-320 Notifier LCM-320

Up to 12,500 feet (3,810 m) on a Class B (Style 4) SLC loop(twisted-unshielded)
Built-in degraded mode increases survivability
Very simple installation - plug-in style
Permits multiple loops in small enclosure.

Notifier NBG-12LX Notifier NBG-12LX

Shipping Weight: 9.6 oz. (272.15 g)
Normal operating voltage: 24 VDC
Maximum SLC loop voltage: 28.0 VDC
Maximum SLC standby current: 375 μ A
Maximum SLC alarm current: 5 mA
Temperature Range: 32°F to 120°F (0°C to 49°C)
Relative Humidity: 10% to 93% (noncondensing)
For use indoors in a dry location

Notifier NFS2-640 Notifier NFS2-640

Signaling Line Circuits (SLCs) 1 expandable to 2
159 detectors/159 modules per SLC
Notification Appliance Circuits (NACs) 4 (built in); 1.5 amps
Voice Evacuation Available Yes: with integrated Digital Voice Command
Power 6 amps total system power Annunciators 32 LCD type 32 ACS type
Networkable Yes: NOTI-FIRE-NET

Notifier NFS-320E Notifier NFS-320E

Signaling Line Circuits (SLCs)1
Intelligent Devices 318: (159 detectors/159 modules)
Notification Appliance Circuits (NACs) 4 (built in): 1.5 amps
Voice Evacuation Available Yes: Direct integration with FirstCommand 50/100
Power 6 amps total system power
Annunciators 32 LCD type, 32 ACS type
Networkable Yes: NOTI-FIRE-NET

Asenwareasenware_2100 Asenware AW-AFP2100

New generation high-speed microprocessor technology;
Operating interfaces simulate the menus and interfaces of Windows;
Non-polarity two-bus intelligent alarm linkage mode adoption;
Controllable standard PS/2 computer keyboard and mouse as on-site programming devices;
Each detector sensitivity adjustable;
7.4'LCD back-light display;
Windows menu and inteface;
English interface and panel display;

Conventional Fire Alarm System Top of page Top
Notifier SD-651 Notifier SD-651

Operating Voltage/Alarm Current: See Adapter Base
Standby Current: 85μA Standby
Sensitivity: 1 - 3.18%/ft
Height: 2.0” in B401
Diameter: 4.1” installed in B401; 6.1” installed in B110LP
Shipping Weight: 5.2 oz
Construction: Flame retardant thermoplastic
Temperature: Photo: 32°F to 120°F (0°C to 49°C)

Notifier FST-851 Notifier 5600 Series

Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise
135°F or 194°F ratings
Plain housing for residential installations (Model 5601P)
Easy-to-use terminal screws
A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring
Reversible mounting bracket

Silent Knight SK-5208 Silent Knight SK-5208

Operating Voltage: 24 VDC
Primary AC: 120 Vrms @ 60Hz, 2A
Total DC Load: 6 Amp
Current Draw: Standby: 140 mA
Alarm: 460 mA
Operating Temp: 32° to 120° F (0° to 49° C)

System Sensor SSM/SSV Series Alarm Bells System Sensor SSM/SSV Series Alarm Bells

Approved for indoor and outdoor use
Low current draw
High dB output
Available in six-inch, eight-inch, and ten-inch sizes
AC and DC models
DC models polarized for use with supervision circuitry
Mount directly to standard four-inch square electrical box indoors
SSM and SSV series come pre-wired

Notifier NBG-12S Notifier NBG-12S

Shipping Weight: 9.6 oz. (272.15 g)
Normal operating voltage: 24 VDC
Maximum SLC loop voltage: 28.0 VDC
Maximum SLC standby current: 375 μ A
Maximum SLC alarm current: 5 mA
Temperature Range: 32°F to 120°F (0°C to 49°C)
Relative Humidity: 10% to 93% (noncondensing)
For use indoors in a dry location

Notifier SFP-2404 Notifier SFP-2404

Initiating Device Circuits
Notification Appliance Circuits (NACs)
Voice Evacuation Available Yes: requires direct connect to FireVoice 25/50 Power
3.0 amps total system power;
SFP-2404 expandable to 6 amps

Asenware AW-CBL2166-A-6 Asenware AW-CBL2166-A-6

Diameter : 6"(150mm)
Volume(dB) : 95
Work Voltage: DC6V/DC12V/DC24V/AC110V/AC230V

Asenware AW-CFP2166-08 Asenware AW-CFP2166-08

Mains supply voltage : 110VAC or 240VAC
Maximum number of manual call points per zone
Output type : NC and NO relay

Asenware AW-CTD821 Asenware AW-CTD821

Operating Voltage Range 9 to 28 VDC Volts Non-polarized
Standby Current ≤120µA @ 24 VDC
Maximum Alarm Current (LED on) ≤15mA@24VDC (1K Ohm current-limiting resistance)
Operating Humidity Range ≤95%RH(40ºC±2ºC) Relative Humidity, Non-condensing
Operating Temperature Range -10ºC to 50ºC (14ºF to 122ºF)

Asenware AW-CMC2166-1 Asenware AW-CMC2166-1

Working Voltage: 220VAC/50Hz or 24VDC
Maximum Current: 5A (220VAC/50Hz) or 8A(24VDC)
Contactor Resistance: ≤0.1
Working Temperature: -10~+50ºC
Relative Humidity: max ≤93±2%

Asenware AW-CSD811 Asenware AW-CSD811

Operating Voltage Range: 9 to 28 VDC Volts Non-polarized
Standby Current: ≤120µA @ 24 VDC
Maximum Alarm Current (LED on: ) ≤15mA @ 24 VDC
(1k Ohm current-limiting resistance)
Operating Humidity Range: ≤95% Relative Humidity, Non-condensing

   

Contact Us

  • Building C 1, Room No(004), HninSi Street, Sinmalite Highway Complex,
    6th Quarter, Kamayut Township,
    Yangon, Myanmar

    telephone Hot Line : (+95)9 450 450 706
    telephone (+95)1-534614, 1-513221 | Fax: (+95)1-534614
    Email sales@ut-s.com, services@ut-s.com, project@ut-s.com
    Website http://www.ut-s.com

    Singapore Address : UTS Trading Pte Ltd, 111 North Bridge Road, #13-01 Peninsula Plaza, Singapore 179098